INSPECTION:
Carefully unpack and inspect the OASIS PLUS for shipping damage. Each unit is tested and
inspected before shipment. Any damage incurred is the responsibility of the carrier, who
should be notified immediately.
All cleaning and maintenance work should be completed before
using the Ozone machine.
Ozone treatment should be the final step in room maintenance.
NOTE: the air flowing into the machine must be clean and dry.
NOTE: if the air intake filter is dirty or missing warranty is voided.
OPERATION:
NOTE: OZONE IS A TOXIC GAS. FOLLOW ALL SAFETY PRECAUTIONS.
1. Make certain all people, pets, and plants are out of area. Close all windows and doors.
2. Make sure the filter in front of the cooling fan is installed and is clean.
3. Place the Oasis Plus unit on a shelf or tabletop as high as possible in the area to be treated.
4 Plug the power cord into a grounded, 3-prong outlet.
5. Set the timer to the desired length of time. Momentarily pressing the UP timer button for one second
will increase the time setting by one minute at a time. Hold the button for 1 -3 seconds to change
the time value by two minutes per second. Hold the button for longer than 3 seconds and the time
setting will change in 20 minutes increments. The maximum time setting is 29:59 hours. After
reaching the maximum time, the timer will wrap back to 00:00 and then continue increasing. When
the time is being decreased and reaches 00:00, it will wrap to 29:59 and continue decreasing.
6. Select the desired power level: 25%; 50%; 75% 100%. The Oasis Plus always defaults to 100%
when you plug it in. When the output level is set to 100%, the machine makes ozone continuously
until the timer runs out or the OFF button is pressed. At other power level settings, the machine will
produce ozone for the fraction of a minute the level is set at. For example, if the output level is set to
75%, the machine will produce ozone for 75% (45 seconds) of each minute. At 50%, ozone is
generated for 30 seconds of each minute, and at 25%, the ozone generation lasts for 15 seconds of
each minute. On any setting other than 100%, the ozone generator will be cycling the ozone ON and
OFF.
7. Turn the unit on by pressing the ON button.
Leave the area immediately.
8. When treatment is complete, unplug the ozone machine and ventilate the area completely until all
smell of ozone is gone. Do NOT allow people, pets, or plants back into the area until all smell of
ozone has dissipated.